MDR-1 Rabbit Monoclonal Antibody(ARB986)

Key features and details

  • Target: MDR-1
  • Clone ID: ARB986
  • Source/Host: Rabbit
  • Reactivity: Human
  • Applications: IHC
  • Dilution: 1:100-1:200
  • Clonality: Monoclonal
  • Storage: at-20°C
  • Brand:
CAT.NO. : ARB6778
US$ Please choose
US$ Please choose
Size:
1mL
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
ABCB1 belongs to the Mdr/Tap subfamily of the ATP-binding cassette transporter superfamily. Multidrug resistance 1 (MDR1) serves as an efflux pump for xenobiotic compounds with broad substrate specificity. MDR1 substrates include therapeutic agents such as actinomycin D, etoposide, imatinib, and doxorubicin, as well as endogenous molecules including β-amyloids, steroid hormones, lipids, phosphatide, cholesterol, and cytokines. Intracellular MDR1 has been detected in the ER, vesicles, and nuclear envelope, and has been associated with cell trafficking machinery. Other reported functions of MDR1 include viral resistance, cytokine trafficking, and lipid homeostasis in the peripheral and central nervous system. MDR1 expressed in the plasma membrane of cells in the blood-brain, blood-cerebral spinal fluid, or blood-placenta barriers restricts the permeability of drugs into these organs from the apical or serosal side. MDR1 is also expressed in normal tissues with excretory function such as small intestine, liver, and kidney. Research studies have shown that MDR1 reduces drug accumulation in cancer cells, allowing the development of drug resistance.
Application
To ensure optimal assay performance, AREX recommends conducting reagent titration tailored to each testing system for optimal detection results.

Application

Dilution Ratio

IHC

1:100 - 1:200

*Results are sample-specific. Please refer to your local assay conditions and test parameters for reference.
Overview

Predicted Molecular Wt

141kDa

Purity

ProA affinity purified IgG

Subcellular location

Membrane

Swissprot ID

P08183

Immunogen

Synthetic peptide.

Storage Buffer

PBS 59%, Sodium azide 0.01%, Glycerol 40%, BSA 0.05%

Recommended method

Heat induced epitope retrieval with Tris-EDTA buffer (pH 9.0), primary antibody incubate at RT (18℃-25℃) for 30 minutes

Alternative Names

ATP-dependent translocase ABCB1 (ATP-binding cassette sub-family B member 1) (Multidrug resistance protein 1) (EC 7.6.2.2) (P-glycoprotein 1) (Phospholipid transporter ABCB1) (EC 7.6.2.1) (CD antigen CD243)

Gene Symbol

ABCB1

Entrez Gene

5243

*AREX continuously optimizes our products. Webpage content may not reflect the latest updates. For inquiries, please contact info@arexbio.com or your local distributor.
*Clone Number, Reactivity, Source/Host and Clonality can be found in the product name and Key Features section above.
Data

Immunohistochemical staining of human kidney tissue using MDR-1 Rabbit Monoclonal Antibody(ARB986).

Storage
Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
Note
For Research Use Only. Not for diagnostic, therapeutics, prophylactic or in vivo use.
FAQs
Are the pathology antibodies provided by AREX raw antibodies or ready-to-use solutions?
AREX Biosciences specializes in supplying high-quality IHC pathology raw antibodies (Raw Antibodies). We do not manufacture ready-to-use working solutions or IVD diagnostic reagents. We mainly provide concentrated raw materials to pathology reagent manufacturers and diagnostic platform companies to support product development and OEM production.
What development scenarios are pathology raw antibodies mainly used for?
Our raw antibodies are primarily used for the research, performance optimization, validation, and commercial-scale production of pathology IHC detection reagents. They are also suitable for companion diagnostics (CDx) projects and antibody screening.
How can I evaluate whether a raw antibody is suitable for our staining platform?
It is recommended to focus on specificity, sensitivity, background control, and performance on your target automated platforms (such as Roche Ventana, Leica Bond, Agilent Dako, etc.). We can provide internal test data for reference, but we recommend partners perform actual validation on their own platforms.
Can you provide samples for platform validation?
Yes. We can provide validation samples depending on the specific product. Some products may be provided free of charge, while others may involve a small sample fee. Handling fee and shipping fee will be charged separately. Please contact us for detailed confirmation.
How should raw antibodies be paired with detection systems?
AREX raw antibodies can be used with various polymer detection systems and ancillary reagents. We recommend optimization in combination with the ARExVisual® system or your existing detection platform to achieve better signal intensity and background control.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. Sitemap
0.176397s