Human CXCL6/GCP-2 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 4.34 pg/ml (50 μl);13.58 pg/ml (10 μl);
  • Standard Curve Range: 31.25~2000 pg/ml
  • Standard Curve Gradient: 7 Points
  • Number of Incubations: 2
  • Sample Volume: 50 μl/10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEH0165
US$ Please choose
US$ Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
GCP-2 (granulocyte chemotactic protein-2) is a CXC chemokine. Among human CXC chemokines, GCP-2 is most closely related to ENA-78. The structure and sequence of the genes for human GCP-2 and ENA-78 also exhibit close similarity, suggesting the two genes may have originated from a recent gene duplication. LIX (LPS-induced CXC chemokine) was initially cloned as a gene induced by LPS in mouse fibroblasts. The mouse protein designated GCP-2, because of its amino acid sequence similarity (60%) to human GCP-2, is identical to the LIX protein sequence.
Typical data

pg/ml

O.D.

Average

Corrected

0.00

0.0073

0.0077

0.0075

31.25

0.0185

0.0197

0.0191

0.0116

62.50

0.0450

0.0437

0.0444

0.0369

125.00

0.1488

0.1519

0.1504

0.1429

250.00

0.5995

0.6087

0.6041

0.5966

500.00

1.6640

1.7040

1.6840

1.6765

1000.00

2.9450

2.9480

2.9465

2.9390

2000.00

3.8530

3.8660

3.8595

3.8520

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

139.4

425.2

854.1

107.3

323.6

710.4

Standard Deviation

6.7

8.8

16.6

3.6

19.4

26.5

Coefficient of Variation(%)

4.8

2.1

1.9

3.4

6.0

3.7

Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human CXCL6/GCP-2 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 90% to 118% with an overall mean recovery of 108%.
Sample Values
Sample Matrix Sample Evaluated Range (pg/ml) Detectable (%) Mean of Detectable (pg/ml)
Serum 30 18.88-92.95 100 55.65
Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of CXCL6/GCP-2 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.