Alpha Tubulin Rabbit Polyclonal antibody

Key features and details

  • Target: Alpha Tubulin
  • Host: Rabbit
  • Reactivity: Human, Mouse, Rat
  • Clonality: Polyclonal
  • Application: WB, IHC, IP, ICC/IF, FC
  • Storage: -20°C
  • Brand:
CAT.NO. : ARA6460
US$ Please choose
US$ Please choose
Size:
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
There are five tubulins in human cells: alpha, beta, gamma, delta, and epsilon. Tubulins are conserved across species. They form heterodimers, which multimerize to form a microtubule filament. An alpha and beta tubulin heterodimer is the basic structural unit of microtubules. The heterodimer does not come apart once formed. The alpha and beta tubulins, which are each about 55 kDa MW, are homologous but not identical. Alpha tubulin is useful for scientists across fields as an internal control due to its high, ubiquitous expression pattern.
Application
To ensure optimal assay performance, AREX recommends conducting reagent titration tailored to each testing system for optimal detection results.

Application

Dilution Ratio

WB

1:2000 - 1:50000

IP

0.4-4.0 µg for 1.0-4.0 mg of total protein lysate

IHC

1:100 - 1:500

IF/ICC

1:100 - 1:500

FC

0.50 µg per 10^6 cells in a 100 µl suspension

*Results are sample-specific. Please refer to your local assay conditions and test parameters for reference.
Overview

Reactivity

Human, Mouse, Rat

Isotype

Rabbit / IgG

Class

Polyclonal

Type

Antibody

Immunogen

Recombinant human Tubulin-Alpha protein

Full Name

tubulin, alpha 1b

Calculated Molecular Weight

50 kDa

Observed Molecular Weight

50-55 kDa

Gene Symbol

Alpha Tubulin

Gene ID (NCBI)

10376

Conjugate

Unconjugated

*AREX continuously optimizes our products. Webpage content may not reflect the latest updates. For inquiries, please contact info@arexbio.com or your local distributor.
*Clone Number, Reactivity, Source/Host and Clonality can be found in the product name and Key Features section above.
Data

Various lysates were subjected to SDS PAGE followed by western blot with Alpha Tubulin Rabbit Polyclonal antibody at dilution of 1:10000 incubated at room temperature for 1.5 hours.

Immunohistochemical analysis of paraffin-embedded human colon cancer tissue slide using Alpha Tubulin Rabbit Polyclonal antibody at dilution of 1:200 (under 10x lens). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0).

Immunofluorescent analysis of (4% PFA) fixed HeLa cells using Alpha Tubulin Rabbit Polyclonal antibody at dilution of 1:200 and Fluor 488-Conjugated AffiniPure Goat Anti-Rabbit IgG(H+L), Fluor 594-Phalloidin (red).

IP result of Alpha Tubulin Rabbit Polyclonal antibody (IP:3ug; Detection:1:1000) with HeLa cells lysate 5000ug.

1x10^6 HEK-293 cells were intracellularly stained with 0.5 ug Alpha Tubulin Rabbit Polyclonal antibody and Fluor 488-Conjugated Goat Anti-Rabbit IgG(H+L) (red), or 0.5 ug rabbit IgG isotype control (blue). Cells were fixed with 4% PFA and permeabilized with Flow Cytometry Perm Buffer.

Storage
Shipped at 4℃. Store at -20℃ for one year. Avoid repeated freeze/thaw cycles.
Note
For Research Use Only. Not for diagnostic, therapeutics, prophylactic or in vivo use.
FAQs
What are the main types of research antibodies and how do they differ?
Research antibodies are mainly divided into monoclonal antibodies and polyclonal antibodies. Monoclonal antibodies typically offer higher specificity and better batch-to-batch consistency, while polyclonal antibodies often provide stronger affinity but may show more variation between batches. The choice depends on your specific experimental needs.
How can I tell if a research antibody is suitable for my experiment?
It is recommended to carefully review the product datasheet for validated applications, species reactivity, recommended dilutions, and published references. For new antibodies, performing a small-scale validation with positive control samples is usually helpful.
Can improper storage of research antibodies affect experimental results?
Yes. Antibodies are sensitive to temperature, repeated freeze-thaw cycles, and contamination. Improper storage may lead to reduced activity, increased background, or weaker signals. It is best to follow the storage instructions provided in the product datasheet.
Why doesn’t the recommended dilution in the datasheet work well in my experiment?
The recommended dilution is based on the supplier’s test conditions. Factors such as sample type, fixation method, and detection system in your lab can influence the optimal working concentration. Performing a dilution series optimization in your own system is often necessary.
What precautions should I take when using a newly purchased research antibody for the first time?
It is advisable to briefly centrifuge the antibody (especially concentrated or lyophilized ones), then perform a small-scale pilot experiment using the recommended conditions. Recording the batch number and usage date is also helpful for future tracking.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. Sitemap
0.596747s