Human CCL25 ARExSet® antibody pair for ELISA
| pg/ml | O.D. | Average | Corrected | |
| 0.00 | 0.0157 | 0.0198 | 0.0178 | |
| 15.63 | 0.0452 | 0.0427 | 0.0440 | 0.0262 |
| 31.25 | 0.0887 | 0.0919 | 0.0903 | 0.0726 |
| 62.50 | 0.1534 | 0.1570 | 0.1552 | 0.1375 |
| 125.00 | 0.3161 | 0.3286 | 0.3224 | 0.3046 |
| 250.00 | 0.6435 | 0.6399 | 0.6417 | 0.6240 |
| 500.00 | 1.3260 | 1.2750 | 1.3005 | 1.2828 |
| 1000.00 | 2.4210 | 2.4440 | 2.4325 | 2.4148 |
- Optimized capture and detection antibody pairings with recommended concentrations save lengthy development time
- Development protocols are provided to guide further assay optimization
- Assay can be customized to your specific needs
- Economical alternative to complete kits
- Capture Antibody
- Detection Antibody
- Recombinant Standard
- Streptavidin conjugated to horseradish-peroxidase (Streptavidin-HRP)
ARExSet®Ancillary Reagent Kit (5 plates): containing 96 well microplates, plate sealers, substrate solution, stop solution, plate coating buffer (PBS), wash buffer, and assay buffer.
96 well microplates: AREX Biosciences, Catalog # DSEP01.
Plate Sealers: AREX Biosciences, Catalog # DSSF01.
Coating Buffer: 137 mM NaCl, 2.7 mM KCl, 8.1 mM Na2HPO4, 1.5 mM KH2PO4, pH 7.2-7.4, 0.2 μm filtered . AREX Biosciences, Catalog # DSCB01.
Blocking Buffer: AREX Biosciences, Catalog # DSBB01.
Wash Buffer: 0.05% Tween 20 in PBS, pH 7.2-7.4. AREX Biosciences, Catalog # DSWB01.
Assay Buffer: 0.5%BSA, 0.05%Tween20, PBS Solution.AREX Biosciences, Catalog # DSAB01
Substrate Solution: Tetramethylbenzidine. AREX Biosciences, Catalog # DSTS01.
Stop Solution: 0.5 mol/ml H2SO4. AREX Biosciences, Catalog # DSSS01.