Helicobactor pylori Rabbit Monoclonal Antibody(ARB587)

Key features and details

  • Target: Helicobactor pylori
  • Clone ID: ARB587
  • Source/Host: Rabbit
  • Reactivity: Helicobacter pylori
  • Applications: IHC
  • Dilution: 1:100-1:200
  • Clonality: Monoclonal
  • Storage: at-20°C
  • Brand:
CAT.NO. : ARB6879
US$ Please choose
US$ Please choose
Size:
1mL
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
Helicobacter pylori is a spiral-shaped, microaerophilic, Gram-negative bacterium that colonizes the human gastric mucosa, utilizing polar flagella for motility and adhering to epithelial cells via adhesins (e.g., BabA, SabA). Its primary biological functions center on surviving the acidic gastric environment through urease activity, which hydrolyzes urea into ammonia and bicarbonate to neutralize stomach acid, establishing a niche for chronic persistence. The detection of Helicobacter pylori in clinical pathology specimens, primarily through histological examination of gastric biopsies (using stains such as Giemsa, Warthin-Starry or immunohistochemistry), provides critical diagnostic information. This is achieved by directly confirming active infection and visually correlating the bacteria's presence with the type and severity of associated mucosal damage, including chronic active gastritis, glandular atrophy, intestinal metaplasia and mucosal lymphoid follicles.
Application
To ensure optimal assay performance, AREX recommends conducting reagent titration tailored to each testing system for optimal detection results.

Application

Dilution Ratio

IHC

1:100 - 1:200

*Results are sample-specific. Please refer to your local assay conditions and test parameters for reference.
Overview

Predicted Molecular Wt

N/A

Species Cross-reactivity

Helicobacter pylori

Purity

ProA affinity purified IgG

Subcellular location

Positive overall cytoplasm of Helicobacter pylori (gastric mucosal epithelium)

Swissprot ID

N/A

Immunogen

Tissue, cells or virus.

Storage Buffer

PBS 59%, Sodium azide 0.01%, Glycerol 40%, BSA 0.05%

Recommended Method

Heat induced epitope retrieval with Tris-EDTA buffer (pH 9.0), primary antibody incubate at RT (18℃-25℃) for 30 minutes.

*AREX continuously optimizes our products. Webpage content may not reflect the latest updates. For inquiries, please contact info@arexbio.com or your local distributor.
*Clone Number, Reactivity, Source/Host and Clonality can be found in the product name and Key Features section above.
Data

Immunohistochemical staining of human stomach tissue using Helicobactor pylori Rabbit Monoclonal Antibody(ARB587)

Storage
Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
Research Use Only
For Research Use Only. Not for diagnostic, therapeutics, prophylactic or in vivo use.
FAQs
Are the pathology antibodies provided by AREX raw antibodies or ready-to-use solutions?
AREX Biosciences specializes in supplying high-quality IHC pathology raw antibodies (Raw Antibodies). We do not manufacture ready-to-use working solutions or IVD diagnostic reagents. We mainly provide concentrated raw materials to pathology reagent manufacturers and diagnostic platform companies to support product development and OEM production.
What development scenarios are pathology raw antibodies mainly used for?
Our raw antibodies are primarily used for the research, performance optimization, validation, and commercial-scale production of pathology IHC detection reagents. They are also suitable for companion diagnostics (CDx) projects and antibody screening.
How can I evaluate whether a raw antibody is suitable for our staining platform?
It is recommended to focus on specificity, sensitivity, background control, and performance on your target automated platforms (such as Roche Ventana, Leica Bond, Agilent Dako, etc.). We can provide internal test data for reference, but we recommend partners perform actual validation on their own platforms.
Can you provide samples for platform validation?
Yes. We can provide validation samples depending on the specific product. Some products may be provided free of charge, while others may involve a small sample fee. Handling fee and shipping fee will be charged separately. Please contact us for detailed confirmation.
How should raw antibodies be paired with detection systems?
AREX raw antibodies can be used with various polymer detection systems and ancillary reagents. We recommend optimization in combination with the ARExVisual® system or your existing detection platform to achieve better signal intensity and background control.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. Sitemap
0.213565s