SLC26A2 Rabbit Polyclonal Antibody

Key features and details

Rabbit polyclonal antibody to SLC26A2
  • Target: SLC26A2
  • Source/Host: Rabbit
  • Reactivity: Human,Mouse,Rat
  • Clonality: Polyclonal
  • Applications: WB,IHC,IF/ICC,FC,ELISA
  • Conjugation: Unconjugated
  • Storage: at -20°C
  • Brand:
CAT.NO. : ARA6301
US$ Please choose
US$ Please choose
Size:
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
SLC26A2, also known as DTDST, is a sulfate transporter encoded by the solute carrier family 26 member 2 gene. It participates in sulfate uptake and transport, supporting proteoglycan sulfation in cartilage and other tissues. SLC26A2 dysfunction has been associated with skeletal development disorders and altered extracellular matrix biology.
Application
To ensure optimal assay performance, AREX recommends conducting reagent titration tailored to each testing system for optimal detection results.

Application

Dilution Ratio

WB

1:500 - 1:2000

IHC

1:2000 - 1:8000

IF/ICC

1:200 - 1:800

FC

0.40 μg per 10^6 cells in a 100 μL suspension

ELISA

User optimized

*Results are sample-specific. Please refer to your local assay conditions and test parameters for reference.
Overview

Description

Rabbit polyclonal antibody to SLC26A2

Specificity

Recognizes SLC26A2 protein

Antibody Type

Primary antibody

Immunogen

Recombinant human SLC26A2 protein, 1-112 aa.

Purification

Antigen affinity purification

Molecular Weight

Predicted: 82 kDa; Observed: 68 kDa

Form/Buffer

Liquid in PBS with 0.02% sodium azide and 50% glycerol, pH 7.3.

Alternative Names

DTD; DTDST; solute carrier family 26 member 2

Gene Symbol

SLC26A2

Entrez Gene

1836(Human);

SwissProt

P50443(Human);

*AREX continuously optimizes our products. Webpage content may not reflect the latest updates. For inquiries, please contact info@arexbio.com or your local distributor.
*Clone Number, Reactivity, Source/Host and Clonality can be found in the product name and Key Features section above.
Data

Mouse colon tissue was subjected to SDS PAGE followed by western blot with SLC26A2 antibody at dilution of 1:1000. Predicted molecular weight: 82 kDa; observed molecular weight: 68 kDa.

Immunohistochemical analysis of paraffin-embedded human colon tissue using SLC26A2 antibody at dilution of 1:4000. Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0).

Immunofluorescent analysis of ethanol-fixed HepG2 cells using SLC26A2 antibody at dilution of 1:400 and AREX® Fluor 488-conjugated goat anti-rabbit IgG.

Storage
Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
Note
For Research Use Only. Not for diagnostic, therapeutics, prophylactic or in vivo use.
FAQs
What are the main types of research antibodies and how do they differ?
Research antibodies are mainly divided into monoclonal antibodies and polyclonal antibodies. Monoclonal antibodies typically offer higher specificity and better batch-to-batch consistency, while polyclonal antibodies often provide stronger affinity but may show more variation between batches. The choice depends on your specific experimental needs.
How can I tell if a research antibody is suitable for my experiment?
It is recommended to carefully review the product datasheet for validated applications, species reactivity, recommended dilutions, and published references. For new antibodies, performing a small-scale validation with positive control samples is usually helpful.
Can improper storage of research antibodies affect experimental results?
Yes. Antibodies are sensitive to temperature, repeated freeze-thaw cycles, and contamination. Improper storage may lead to reduced activity, increased background, or weaker signals. It is best to follow the storage instructions provided in the product datasheet.
Why doesn’t the recommended dilution in the datasheet work well in my experiment?
The recommended dilution is based on the supplier’s test conditions. Factors such as sample type, fixation method, and detection system in your lab can influence the optimal working concentration. Performing a dilution series optimization in your own system is often necessary.
What precautions should I take when using a newly purchased research antibody for the first time?
It is advisable to briefly centrifuge the antibody (especially concentrated or lyophilized ones), then perform a small-scale pilot experiment using the recommended conditions. Recording the batch number and usage date is also helpful for future tracking.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. Sitemap