Plasmid DNA Residual (qPCR) Detection Kit(Gentamicin)

Key features and details

  • Linear Range: 1×10^6- 1×10^1 copies/μL
  • Standard Curve Linearity: R² ≥ 0.980;Amplification Efficiency 90% ≤ Eff (%) ≤ 110%;CV < 15% for all concentration detection values
  • Accuracy (Spiked Recovery): 70%–130%
  • Limit of Quantification: 5 copies/μL, CV ≤ 20%, measurement deviation ≤ |±20%|
  • Precision (repeatability): Ten replicates each for high and medium concentration reference samples, with coefficient of variation (CV) <15%
  • Negative control compliance rate: NTCs must yield Undetermined results or Ct values >35
  • Compatible instruments (including but not limited to): ABI QuantStudio 5, ABI 7500, etc
  • Brand:
CAT.NO. : ARK6620
US$ Please choose
US$ Please choose
Size:
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
In May 2022, the Technical Guidelines for Pharmaceutical Research and Evaluation of In Vivo Gene Therapy Products issued by the Center for Drug Evaluation (CDE) explicitly stated that viral vectors such as AAV, which easily package non-vector DNA into viral particles, should consider the potential risk of foreign DNA packaging during plasmid selection for viral production. Regulatory authorities require that the DNA content in the final product of cell expression should be minimized and quantified using highly sensitive methods. General Chapter 3407 of the Chinese Pharmacopoeia (Volume III) designates DNA probe hybridization, fluorescence staining, and quantitative PCR (qPCR) as the standard methods for detecting host cell DNA residues. The detection linear range of this kit is 1×10^6 copies/μL - 1×10^1 copies/μL with a sensitivity of up to 5 copies/μL, which can meet the customer needs and quantify the DNA residue accurately and rapidly.
Overview

Linear Range

1×10^6- 1×10^1 copies/μL

Standard Curve Linearity

R² ≥ 0.980;
Amplification Efficiency 90% ≤ Eff (%) ≤ 110%;CV < 15% for all concentration detection values

Accuracy (Spiked Recovery)

70%–130%

Limit of Quantification

5 copies/μL, CV ≤ 20%, measurement deviation ≤ |±20%|

Precision (repeatability)

Ten replicates each for high and medium concentration reference samples, with coefficient of variation (CV) <15%

Negative control compliance rate

NTCs must yield Undetermined results or Ct values >35

Compatible instruments (including but not limited to)

ABI QuantStudio 5, ABI 7500, etc

Storage
The kit should be stored at -20°C or below, with a shelf life of 12 months. Please note that any unused portions of the kit after opening should still be stored under the specified storage conditions.
Note
For Research Use Only. Not for diagnostic, therapeutics, prophylactic or in vivo use.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.