Mouse CD163 ELISA Kit (one step)
Sensitivity | 0.02 ng/ml (10 μl) |
Standard Curve Range | 15.63-1000 ng/ml |
Standard Curve Gradient | 7 Points |
Number of Incubations | 1 |
Detectable Sample | serum, plasma |
Sample Volume | 10 μl |
Type | Fully Ready-to-Use |
Operation Duration | 90min |
Alternative Names | |
Gene Symbol | Cd163 |
Entrez Gene | 93671 (Mouse) |
SwissProt | Q2VLH6 (Mouse) |

<table><tr><td>ng/ml</td><td>O.D.1</td><td>O.D.2</td><td>Average</td><td>Corrected</td></tr><tr><td>0.00</td><td>0.0058</td><td>0.0062</td><td>0.0060</td><td></td></tr><tr><td>15.63</td><td>0.0399</td><td>0.0316</td><td>0.0358</td><td>0.0298</td></tr><tr><td>31.25</td><td>0.0761</td><td>0.0849</td><td>0.0805</td><td>0.0745</td></tr><tr><td>62.50</td><td>0.1626</td><td>0.1407</td><td>0.1517</td><td>0.1457</td></tr><tr><td>125.00</td><td>0.3227</td><td>0.3244</td><td>0.3236</td><td>0.3176</td></tr><tr><td>250.00</td><td>0.6385</td><td>0.6747</td><td>0.6566</td><td>0.6506</td></tr><tr><td>500.00</td><td>1.1360</td><td>1.2650</td><td>1.2005</td><td>1.1945</td></tr><tr><td>1000.00</td><td>2.6280</td><td>2.6700</td><td>2.6490</td><td>2.6430</td></tr></table>
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average(ng/ml) | 28.3 | 157.5 | 346.9 | 34.0 | 149.5 | 345.8 |
| Standard Deviation | 2.2 | 11.2 | 15.6 | 1.7 | 11.1 | 18.9 |
| Coefficient of Variation(%) | 7.7 | 7.1 | 4.5 | 5.0 | 7.4 | 5.5 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty-two times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess inter-assay precision.
The spike recovery was evaluated by spiking 3 levels of mouse CD163 into health mouse serum sample. The un-spiked serum was used as blank in this experiment. The recovery ranged from 90% to 120% with an overall mean recovery of 98%.
| Sample Matrix | Sample Evaluated | Range (ng/ml) | Detectable (%) | Mean of Detectable (ng/ml) |
|---|---|---|---|---|
| Mouse Serum | 30 | 58.63-152.00 | 100 | 80.70 |
n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
FAQs
New Products
Instruction