MASH1/Achaete-scute homolog 1 Mouse Monoclonal Antibody(ARA620)

Key features and details

Mouse monoclonal antibody to MASH1/ASCL1
  • Target: MASH1/Achaete-scute homolog 1
  • Clone ID: ARA620
  • Source/Host: Mouse
  • Reactivity: Human
  • Clonality: Monoclonal
  • Applications: IHC
  • Storage: at-20°C
  • Brand:
CAT.NO. : ARA6320
US$ Please choose
US$ Please choose
Size:
1mL
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
MASH1/ASCL1 encodes a member of the basic helix-loop-helix (bHLH) family of transcription factors. It plays a role in the early stages of neuronal lineage development and is essential for generation of olfactory and autonomic neurons. Activates transcription by binding to E box (5'-CANNTG-3').
Application
To ensure optimal assay performance, AREX recommends conducting reagent titration tailored to each testing system for optimal detection results.

Application

Dilution Ratio

IHC

1:50-1:100

*Results are sample-specific. Please refer to your local assay conditions and test parameters for reference.
Overview

Description

Mouse monoclonal antibody to MASH1/ASCL1

Specificity

Recognizes MASH1/ASCL1 (Achaete-scute homolog 1)

Antibody Type

Primary antibody

Immunogen

Recombinant protein corresponding to human MASH1/ASCL1

Molecular Weight

Predicted: 25 kDa; Observed: ~30 kDa

Purification

Protein A affinity purified

Isotype

IgG

Form/Buffer

50% Glycerol/PBS with 1% BSA and 0.09% sodium azide

Alternative Names

ASCL1; Achaete-scute complex homolog 1; ASH1; HASH1; bHLHa46

Gene Symbol

ASCL1

Entrez Gene

429(Human); 17172(Mouse)

SwissProt

P50553(Human); Q02067(Mouse)

*AREX continuously optimizes our products. Webpage content may not reflect the latest updates. For inquiries, please contact info@arexbio.com or your local distributor.
*Clone Number, Reactivity, Source/Host and Clonality can be found in the product name and Key Features section above.
Data

Immunohistochemical analysis of MASH1/ASCL1 staining in human lung cancer tissue using MASH1/Achaete-scute homolog 1 Mouse Monoclonal Antibody(ARA620). Heat mediated antigen retrieval was performed with sodium citrate buffer (pH 6.0), followed by HRP polymer detection and DAB chromogen.

Immunohistochemical analysis of MASH1/ASCL1 staining in human small cell lung carcinoma (SCLC) tissue using MASH1/Achaete-scute homolog 1 Mouse Monoclonal Antibody(ARA620). Heat mediated antigen retrieval was performed with sodium citrate buffer (pH 6.0), followed by HRP polymer detection and DAB chromogen.

Storage
Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
Note
For Research Use Only. Not for diagnostic, therapeutics, prophylactic or in vivo use.
FAQs
Are the pathology antibodies provided by AREX raw antibodies or ready-to-use solutions?
AREX Biosciences specializes in supplying high-quality IHC pathology raw antibodies (Raw Antibodies). We do not manufacture ready-to-use working solutions or IVD diagnostic reagents. We mainly provide concentrated raw materials to pathology reagent manufacturers and diagnostic platform companies to support product development and OEM production.
What development scenarios are pathology raw antibodies mainly used for?
Our raw antibodies are primarily used for the research, performance optimization, validation, and commercial-scale production of pathology IHC detection reagents. They are also suitable for companion diagnostics (CDx) projects and antibody screening.
How can I evaluate whether a raw antibody is suitable for our staining platform?
It is recommended to focus on specificity, sensitivity, background control, and performance on your target automated platforms (such as Roche Ventana, Leica Bond, Agilent Dako, etc.). We can provide internal test data for reference, but we recommend partners perform actual validation on their own platforms.
Can you provide samples for platform validation?
Yes. We can provide validation samples depending on the specific product. Some products may be provided free of charge, while others may involve a small sample fee. Handling fee and shipping fee will be charged separately. Please contact us for detailed confirmation.
How should raw antibodies be paired with detection systems?
AREX raw antibodies can be used with various polymer detection systems and ancillary reagents. We recommend optimization in combination with the ARExVisual® system or your existing detection platform to achieve better signal intensity and background control.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. Sitemap