Human Pentraxin 3/PTX3 ELISA Kit

Key features and details

  • Species: Human
  • Size: 5 plates,15 plates,50 plates
  • Sample Volume: 50 μl/10 μl
  • Standard Curve Range: 13.73~10000 pg/ml
  • Assay type: Fully Ready-to-Use
  • Sensitivity: 1.99 pg/ml (50 μl);9.53 pg/ml (10 μl)
  • Operation Duration: 120min
  • Assay type: Sandwich Elisa
  • Brand:
CAT.NO. : AEH0141
US$ Please choose
US$ Please choose
Size:
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
Pentraxin 3 (PTX3), also known as TNF-stimulated gene 14 (TSG-14), is a secreted glycoprotein belonging to the Pentraxin family of proteins. It is the prototypical long Pentraxin, exhibiting a C-terminal Pentraxin domain characteristic of the family, and a unique N-terminal domain. It is produced by several cell types including endothelial and mononuclear cells. PTX3 acts as a pattern recognition receptor with non-redundant roles in the innate immune response to several microbial agents including the fungal pathogen Aspergillus fumigatus. Overexpression leads to enhanced pro-inflammatory responses. PTX3 is induced in response to LPS and inflammatory cytokines including TNF-alpha and IL-1 beta.
typical data

pg/ml

O.D.

Average

Corrected

0.00

0.0431

0.0393

0.0412

 

13.72

0.0704

0.0717

0.0711

0.0299

41.15

0.1370

0.1360

0.1365

0.0953

123.46

0.3247

0.3126

0.3187

0.2775

370.37

0.8276

0.7558

0.7917

0.7505

1111.11

1.7600

1.6140

1.6870

1.6458

3333.33

3.0380

2.8520

2.9450

2.9038

10000.00

3.8390

3.6580

3.7485

3.7073

Precision

Intra-assay Precision

 

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

213.5

1031.5

3290.1

242.9

1110.6

3753.9

Standard deviation

11.3

63.9

223.3

5.3

51.7

224.3

Coefficient of variation(%)

5.3

6.2

6.8

2.2

4.7

6.0


Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human Pentraxin 3/PTX3 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 80% to 118% with an overall mean recovery of 104%.
Sample Values

Sample Matrix

Sample

Evaluated

Range

(pg/ml)

Detectable

%

Mean of Detectable

(pg/ml)

Serum

30

1308.85-6892.74

100

3254.30


Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of Pentraxin 3/PTX3 in this assay. No medical histories were available for the donors.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. Sitemap