Human MIP-5/CCL15 ELISA Kit
Sensitivity | 13.85 pg/ml (50 μl) |
Standard Curve Range | 31.25-2000 pg/ml |
Standard Curve Gradient | 7 Points |
Number of Incubations | 2 |
Detectable Sample | Liquid phase sample of soluble substances. For example: serum, plasma, cell culture supernatant, tissue grinding liquid, etc. |
Sample Volume | 50 μl |
Type | Fully Ready-to-Use |
Operation Duration | 120min |
Alternative Names | Chemokine CC-2, Leukotactin-1, MIP-1 delta, Macrophage inflammatory protein 5, Mrp-2b, NCC-3, Small-inducible cytokine A15 |
Gene Symbol | CCL15, MIP5, NCC3, SCYA15 |
Entrez Gene | 6359 (Human) |
SwissProt | Q16663 (Human) |

<table><tr><td>pg/ml</td><td>O.D.1</td><td>O.D.2</td><td>Average</td><td>Corrected</td></tr><tr><td>0.00</td><td>0.0090</td><td>0.0090</td><td>0.0090</td><td></td></tr><tr><td>31.25</td><td>0.0130</td><td>0.0140</td><td>0.0135</td><td>0.0045</td></tr><tr><td>62.50</td><td>0.0230</td><td>0.0210</td><td>0.0220</td><td>0.0130</td></tr><tr><td>125.00</td><td>0.0540</td><td>0.0490</td><td>0.0515</td><td>0.0425</td></tr><tr><td>250.00</td><td>0.1670</td><td>0.1450</td><td>0.1560</td><td>0.1470</td></tr><tr><td>500.00</td><td>0.5270</td><td>0.5010</td><td>0.5140</td><td>0.5050</td></tr><tr><td>1000.00</td><td>1.6370</td><td>1.5760</td><td>1.6065</td><td>1.5975</td></tr><tr><td>2000.00</td><td>3.2740</td><td>3.2740</td><td>3.2740</td><td>3.2650</td></tr></table>
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average(pg/ml) | 68.2 | 262.6 | 718.7 | 47.7 | 214.8 | 644.6 |
| Standard Deviation | 5.4 | 15.6 | 40.3 | 3.8 | 10.1 | 32.8 |
| Coefficient of Variation(%) | 7.9 | 5.9 | 5.6 | 7.9 | 4.7 | 5.1 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty-two times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
The spike recovery was evaluated by spiking 3 levels of human MIP-5/CCL15 into health human serum sample. The un-spiked serum was used as blank in this experiment. The recovery ranged from 85% to 105% with an overall mean recovery of 97%.
| Sample Matrix | Sample Evaluated | Range (pg/ml) | Detectable (%) | Mean of Detectable (pg/ml) |
|---|---|---|---|---|
| Serum | 30 | 2321.43-15417.02 | 100 | 10905.55 |
n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.