Human IL-7 ARExSet® antibody pair for ELISA

Key features and details

  • Target: IL-7
  • Reactivity: Human
  • Sample Volume: 50 μl
  • Range: 7.81 pg/ml-500 pg/ml
  • Operation Duration: 120min
  • Brand:
CAT.NO. : ASEH0045
US$ Please choose
US$ Please choose
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
IL-7 (Interleukin-7) is a cytokine that plays important roles in lymphocyte differentiation, proliferation, and survival. IL-7 is produced by stromal epithelial cells of the thymus, bone marrow, and intestines. It signals through a receptor complex composed of IL-7 R alpha/CD127 and the Common gamma Chain. gamma c is also a subunit of the receptors for IL-2, -4, -9, -15, and -21. IL-7 contributes to the maintenance of all naïve and memory T cells. It is required for optimal T cell-dendritic cell interaction. In mouse, IL-7 activation of IL-7 R alpha is critical for both T cell and B cell lineage development, while in humans, it is required for T cell but not for B cell development. IL-7 (Interleukin-7) is a cytokine that plays important roles in lymphocyte differentiation, proliferation, and survival. IL-7 is produced by stromal epithelial cells of the thymus, bone marrow, and intestines. It signals through a receptor complex composed of IL-7 R alpha/CD127 and the Common gamma Chain. gamma c is also a subunit of the receptors for IL-2, -4, -9, -15, and -21. IL-7 contributes to the maintenance of all naïve and memory T cells. It is required for optimal T cell-dendritic cell interaction. In mouse, IL-7 activation of IL-7 R alpha is critical for both T cell and B cell lineage development, while in humans, it is required for T cell but not for B cell development.
Overview

Standard Curve Range

7.81 pg/ml-500 pg/ml

Standard Curve Gradient

7 Points/3 Folds

Number of Incubations

2

Detectable Sample

Liquid phase sample of soluble substances. For example: serum, plasma, cell culture supernatant, tissue grinding liquid, etc.

Sample Volume

50 μl

Type

Not Ready-to-Use

Operation Duration

120min

Alternative Names

IL-7, IMD130, interleukin-7

Gene Symbol

IL7

Entrez Gene

3574 (Human)

SwissProt

P13232 (Human)

*AREX continuously optimizes our products. Webpage content may not reflect the latest updates. For inquiries, please contact info@arexbio.com or your local distributor.
Data

<table><tr><td>pg/ml</td><td>O.D.1</td><td>O.D.2</td><td>Average</td><td>Corrected</td></tr><tr><td>0</td><td>0.0220</td><td>0.0215</td><td>0.0218</td><td></td></tr><tr><td>7.81</td><td>0.1179</td><td>0.1023</td><td>0.1101</td><td>0.0884</td></tr><tr><td>15.63</td><td>0.1845</td><td>0.1690</td><td>0.1768</td><td>0.1550</td></tr><tr><td>31.25</td><td>0.3242</td><td>0.2938</td><td>0.3090</td><td>0.2873</td></tr><tr><td>62.50</td><td>0.5629</td><td>0.5228</td><td>0.5429</td><td>0.5211</td></tr><tr><td>125.00</td><td>1.1000</td><td>0.9245</td><td>1.0123</td><td>0.9905</td></tr><tr><td>250.00</td><td>1.9400</td><td>1.6880</td><td>1.8140</td><td>1.7923</td></tr><tr><td>500.00</td><td>2.7260</td><td>2.8470</td><td>2.7865</td><td>2.7648</td></tr></table>

Product Features
• Optimized capture and detection antibody pairings with recommended concentrations save lengthy development time
• Development protocols are provided to guide further assay optimization
• Assay can be customized to your specific needs
• Economical alternative to complete kits
Kit Content
• Capture Antibody
• Detection Antibody
• Recombinant Standard
• Streptavidin conjugated to horseradish-peroxidase (Streptavidin-HRP)
Other Reagents Required
ARExSet® Ancillary Reagent Kit (5 plates): containing 96 well microplates, plate sealers, substrate solution, stop solution, plate coating buffer (PBS), wash buffer, and assay buffer. The components listed above may be purchased separately:
• 96 well microplates: AREX Biosciences, Catalog # DSEP01.
• Plate Sealers: AREX Biosciences, Catalog # DSSF01.
• Coating Buffer: 137 mM NaCl, 2.7 mM KCl, 8.1 mM Na2HPO4, 1.5 mM KH2PO4, pH 7.2-7.4, 0.2 μm filtered. AREX Biosciences, Catalog # DSCB01.
• Blocking Buffer: AREX Biosciences, Catalog # DSBB01.
• Wash Buffer: 0.05% Tween 20 in PBS, pH 7.2-7.4. AREX Biosciences, Catalog # DSWB01.
• Assay Buffer: 0.5%BSA,0.05%Tween20,PBS Solution.AREX Biosciences, Catalog # DSAB01
• Substrate Solution: Tetramethylbenzidine. AREX Biosciences, Catalog # DSTS01.
• Stop Solution: 0.5mol/L H2SO4. AREX Biosciences, Catalog # DSSS01.
Storage
Store components at 4°C or -20°C. Keep microplate wells sealed in a dry bag with desiccants. Do not expose test reagents to heat, sun or strong light during storage and usage. Please refer to the product user manual for detail temperatures of the components.
Note
For Research Use Only. Not for diagnostic, therapeutics, prophylactic or in vivo use.
FAQs
What is the ARExSet® antibody pair for ELISA?
The ARExSet® antibody pair for ELISA is a Do-It-Yourself (DIY) ELISA reagent set containing optimized capture and detection antibody pairs, recombinant standard, and Streptavidin-HRP. It is designed for researchers who need flexibility in developing their own sandwich ELISA assays.
What sample types can be used with the ARExSet® antibody pair?
Suitable samples typically include serum, plasma, cell culture supernatant, tissue grinding liquid, and other liquid phase samples of soluble substances.
How should the ARExSet® antibody pair be stored?
Store components at 4°C or -20°C upon receipt. Reconstituted standards should be used immediately or stored at -20°C. Avoid repeated freeze/thaw cycles.
What other reagents are required to use the ARExSet® antibody pair?
The ARExSet® Ancillary Reagent Kit is required, containing 96-well microplates, plate sealers, coating buffer, blocking buffer, wash buffer, assay buffer, substrate solution, and stop solution. These can be purchased separately.
Can the assay be customized?
Yes. The assay can be customized to your specific needs. Development protocols are provided to guide further assay optimization. The optimized capture and detection antibody pairings save lengthy development time.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. Sitemap