Human CLEC5A ELISA Kit

Key features and details

  • Sensitivity: 10 pg/ml
  • Detection Range: 31.2 pg/ml - 2000 pg/ml
  • Sample Types: Cell Culture Supernatants, Serum and Plasma (heparin, EDTA)
  • Species: Human
  • Detection Method: Sandwich ELISA, Colorimetric
  • Target: CLEC5A
  • Assay Type: Sandwich ELISA
  • Brand:
CAT.NO. : ARE6651
USD Please choose
USD Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
C-type lectin domain family 5 member A (CLEC5A), also known as C-type lectin superfamily member 5 (CLECSF5) and myeloid DAP12-associating lectin 1 (MDL-1), is a C-type lectin that in humans is encoded by the CLEC5A gene. This gene encodes a member of the C-type lectin/C-type lectin-like domain (CTL/CTLD) superfamily. Members of this family share a common protein fold and have diverse functions, such as cell adhesion, cell-cell signalling, glycoprotein turnover, and roles in inflammation and immune response. The encoded type II transmembrane protein interacts with DAP12 and may play a role in cell activation. Alternative splice variants have been described but their full-length sequence has not been determined.
Overview

Product Description

Sandwich Enzyme-Linked Immunosorbent Assay for Quantitative Detection of Human CLEC5A Concentrations in Cell Culture Supernatants, Serum and Plasma.

Sensitivity

10 pg/ml

Detection Method

Colorimetric

Detection Range

31.2 pg/ml - 2000 pg/ml

Sample Type

Cell Culture Supernatants, Serum and Plasma (heparin, EDTA)

Alternative Names

CLECSF5; MDL1; MDL-1; C-type lectin superfamily member 5; Myeloid DAP12-associating lectin 1

Gene Symbol

CLEC5A

Entrez Gene

23601

SwissProt (UniProt)

Q9NY25

*AREX continuously optimizes our products. Webpage content may not reflect the latest updates. For inquiries, please contact info@arexbio.com or your local distributor.
Data

<table style="width:100%;table-layout:fixed;text-align:center;"><tr><td width="50%" style="width:50%">Concentration (pg/ml)</td><td width="50%" style="width:50%">O.D.</td></tr><tr><td width="50%" style="width:50%">0</td><td width="50%" style="width:50%">0.027</td></tr><tr><td width="50%" style="width:50%">31.2</td><td width="50%" style="width:50%">0.158</td></tr><tr><td width="50%" style="width:50%">62.5</td><td width="50%" style="width:50%">0.244</td></tr><tr><td width="50%" style="width:50%">125</td><td width="50%" style="width:50%">0.395</td></tr><tr><td width="50%" style="width:50%">250</td><td width="50%" style="width:50%">0.629</td></tr><tr><td width="50%" style="width:50%">500</td><td width="50%" style="width:50%">1.029</td></tr><tr><td width="50%" style="width:50%">1000</td><td width="50%" style="width:50%">1.635</td></tr><tr><td width="50%" style="width:50%">2000</td><td width="50%" style="width:50%">2.464</td></tr></table>

Precision
Intra-assay Precision Inter-assay Precision
Sample Number S1S2S3S1S2S3
161616242424
Mean(pg/ml) 5128690559310933
Standard Deviation 2.1411.1541.633.0717.0545.72
Coefficient of Variation(%) 4.23.94.65.25.54.9
Storage
Store components at 4°C or -20°C. Keep microplate wells sealed in a dry bag with desiccants. Do not expose test reagents to heat, sun or strong light during storage and usage. Please refer to the product user manual for detail temperatures of the components.
Note
For Research Use Only. Not for diagnostic, therapeutics, prophylactic or in vivo use.
FAQs
What is the principle of these ELISA kits?
The kits are based on the sandwich or competitive ELISA principle, using specific antibodies and enzyme-conjugated detection for quantitative measurement of the target analyte.
What sample types can be used with the ELISA kits?
Suitable samples typically include serum, plasma, cell culture supernatant, tissue homogenates, and other biological fluids. Please check the specific Datasheet for recommended sample types.
How should the kits be stored and what is the shelf life?
Store components at 4°C or -20°C. Keep microplate wells sealed in a dry bag with desiccants. Do not expose test reagents to heat, sun or strong light during storage and usage. Please refer to the product user manual for detail temperatures of the components.
What is the precision and reproducibility of the kits?
The kits are optimized for good intra- and inter-assay precision when performed according to the protocol. Coefficient of variation (CV) values are generally low.
Do you provide technical support or troubleshooting guidance?
Yes. We provide detailed Datasheets, Certificates of Analysis (CoA), and technical support to help with assay performance and troubleshooting.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.